Synchronous motor

How a synchronous motor locks to the field, the load angle and pull-out, damper starting and hunting, power factor control and the V-curve, with a turbo-electric propulsion motor you can start and run yourself.

Machines, page 4 of 65 min readUpdated 18 November 2026All 6 pages

A synchronous motor runs exactly in step with the supply. It is an alternator worked backwards: feed its stator with three-phase power and give its rotor a DC field, and the rotor locks on to the turning field and keeps pace with it, with no slip at all.

An interactive synchronous motor loads here. It needs JavaScript; the sections below explain everything it shows.

Principle of operation

The stator is the same as an induction motor's and makes the same rotating field. The rotor, though, is an electromagnet with fixed north and south poles, fed with direct current through slip rings or from a brushless exciter. Those poles are pulled round by the field like a compass needle following a magnet, and they turn at exactly the synchronous speed, 120 × f ÷ P.

Add load and the rotor drops back behind the field, but not in speed. It runs at exactly the same speed as before, only a few degrees further back. That angle between the rotor's poles and the field's is the load angle, δ.

T ∝ (V × E ÷ Xs) × sin δ
V = supply voltage, E = the voltage the rotor's field induces in the stator, Xs = synchronous reactance, δ = load angle (electrical degrees)

The torque rises with sin δ. Full load is usually reached near δ = 30°, where the torque is about half the most the motor can give. The most it can give comes at δ = 90°: the pull-out torque.

Construction

Turn the lab to Names. A slow propulsion motor needs many poles to turn slowly on a fixed frequency: 120 × 60 ÷ 70 is 102.9 rpm, so a 70-pole motor turns a propeller directly at that speed. The lab's motor is built that way.

PartWhat it does
StatorA laminated core with a three-phase winding in its slots, the same as any AC machine's.
Salient poles and field coilsPoles standing out from the rotor rim, each with a coil carrying the DC field current.
Damper barsCopper bars in the pole faces, joined by end rings: a cage, as in an induction motor. They start the motor and damp its hunting.
Slip rings and brushesBring the DC field current in from a separate supply. Smaller motors use a brushless exciter instead, like a ship's alternator.
SpiderThe arms that carry the heavy rim and poles from the shaft.
Pedestal bearingsOil-lubricated sleeve bearings either side, each on its own pedestal.
Starting

At standstill the field sweeps past the rotor's poles far too fast for them to follow, pulling first one way, then the other. A synchronous motor cannot start by itself. So the rotor also carries a cage winding, the damper or amortisseur winding. The motor starts on it as an induction motor, and when it is close to synchronous speed the DC field is switched on and the rotor pulls into step.

The field can only pull the rotor in when the damper bars have brought it close to synchronous speed. The heavier the load, the further behind the field the bars leave it, as with any induction motor. In the lab, start it on full load and it hangs well below speed; lighten the load and it comes close enough to pull in.

Hunting and the damper winding

When load is added, the rotor does not settle at its new load angle at once. Its inertia carries it past, and it swings back and forth about the new position, slower than the field and then faster. This swinging is hunting. While the rotor moves relative to the field, currents are induced in the damper bars, and their torque opposes the swing until it dies away. In the lab, watch the damper bars glow while the rotor pulls into step, then go dark once it is locked.

Power factor control

Change the DC field current and the motor's power factor changes, without any change of speed. With too little field it is under-excited and draws lagging current like an induction motor; at the right field it runs at unity; with more still it is over-excited and draws leading current, supplying reactive power to the system instead of taking it.

Plot the stator current against the field current at a steady load and the curve has the shape of a V: the V-curve. The bottom of the V is unity power factor, where the current is least. A propulsion motor is run there, so the current, the copper losses and the size of everything that carries it are no larger than the kW demands. A synchronous motor run with no load purely to supply reactive power is a synchronous condenser.

Losing step

Load the motor more and more and the load angle grows. Past 90° the torque begins to fall instead of rise, the rotor cannot hold the field, and it pulls out of step: the poles slip past the field one after another, the torque swings violently, the current surges, and the motor stalls unless it is tripped. Weakening the field does the same, because a weaker field gives less torque at every angle. In the lab, the protection trips the motor after two seconds of slipping poles.

Applications on board
On board: mainly as large propulsion motors on electrically propelled ships, where the steady speed and the adjustable power factor justify the extra complexity. Its larger air gap also suits a long propeller shaft that flexes with the hull. Every ship's alternators are synchronous machines too.
Check yourself
1. What is the slip of a synchronous motor?
Zero: it runs exactly at synchronous speed.
2. How does it get up to speed?
On its damper winding, as an induction motor; then the DC field is switched on and it pulls into step.
3. What happens if you raise its field current well above normal?
It runs at a leading power factor and supplies reactive power.
4. A 70-pole synchronous motor runs on 60 Hz. At what speed?
120 × 60 ÷ 70 = 102.9 rpm, whatever the load.
5. At what load angle does a synchronous motor pull out of step?
Past 90°, where its torque is greatest. Full load is usually near 30°.
6. What stops a synchronous motor hunting?
The damper winding: currents induced in it by the swing make a torque that opposes it.

Going for your ETO CoC oral?

The full Synchronous motor notes (T03), the quiz bank and the questions MMD surveyors have actually asked, each with a model answer, are in the Elec-Buddy app.

Start your free trial

Sources

Where the figures on this page come from, by book and printed page or by regulation.

  • Wadhwa, C.L. Basic Electrical Engineering, chapter 7, three-phase synchronous machines: construction (7.2, p.276), effect of excitation on armature current, under- and over-excitation (7.3, p.291), change of load and hunting about the new load angle (7.4, p.292), starting by damper winding (7.5.1, p.292), the damper winding against hunting (p.293), the torque T proportional to V E sin δ ÷ Xs, full load near δ = 30° at about half the pull-out torque, pull-out at δ = 90° (7.6, p.294), the synchronous condenser (7.7, p.294), applications (7.8, p.296).
  • Fernandez, E.A. Marine Electrical Technology, chapter 17, electrical propulsion: the turbo-electric installation; a slow propulsion motor (about 106 rpm) with a large number of salient poles, its rotor excitation supplied separately, copper bars and end rings for starting, and the starting sequence through the generator (17.7, p.641-642); unity power factor keeping the current to a minimum, the load angle, and pulling out of step (17.8, p.642-643); an induction motor's small air gap suits a propeller shaft poorly because the shaft flexes with the hull (p.647). Loss of synchronism in generators: large circulating currents and severe vibration (p.352).
  • Hall, D.T. Practical Marine Electrical Knowledge, 3rd ed. (2014): large electric propulsion using AC synchronous motors (p.86); the synchronous motor's DC-excited poles locking in synchronism with the stator's rotating flux (p.149); the synchronous compensator (p.52); frequency converters (synchroconverters) for the speed control of synchronous propulsion motors (p.150-155).
  • Turbo-electric tankers (aukevisser.nl, T2 tanker pages): a steam turbine drives a synchronous generator feeding a synchronous propulsion motor, with propeller speed set by the turbine's speed; the 9,000 shp Marinship machinery used a 70-pole motor rated at 103 rpm, or a 60-pole motor at 120 rpm.
  • Elec-Buddy notes: T03 Electric Motors (synchronous motor, damper windings and pull-out).
  • The lab's motor is a model, not a maker's machine: 6.7 MW (9,000 shp), 70 poles, 102.9 rpm on a fixed 60 Hz supply, sized from its torque, driving a load whose torque rises with the square of its speed, solved in real time. Its synchronous reactance is set so full load sits at a load angle of about 31° and pull-out is about twice full load, as Wadhwa gives; its two-second out-of-step trip is the lab's own setting. An automated test checks its figures.