An interactive synchronous motor loads here. It needs JavaScript; the sections below explain everything it shows.
The stator is the same as an induction motor's and makes the same rotating field. The rotor, though, is an electromagnet with fixed north and south poles, fed with direct current through slip rings or from a brushless exciter. Those poles are pulled round by the field like a compass needle following a magnet, and they turn at exactly the synchronous speed, 120 × f ÷ P.
Add load and the rotor drops back behind the field, but not in speed. It runs at exactly the same speed as before, only a few degrees further back. That angle between the rotor's poles and the field's is the load angle, δ.
The torque rises with sin δ. Full load is usually reached near δ = 30°, where the torque is about half the most the motor can give. The most it can give comes at δ = 90°: the pull-out torque.
Turn the lab to Names. A slow propulsion motor needs many poles to turn slowly on a fixed frequency: 120 × 60 ÷ 70 is 102.9 rpm, so a 70-pole motor turns a propeller directly at that speed. The lab's motor is built that way.
| Part | What it does |
|---|---|
| Stator | A laminated core with a three-phase winding in its slots, the same as any AC machine's. |
| Salient poles and field coils | Poles standing out from the rotor rim, each with a coil carrying the DC field current. |
| Damper bars | Copper bars in the pole faces, joined by end rings: a cage, as in an induction motor. They start the motor and damp its hunting. |
| Slip rings and brushes | Bring the DC field current in from a separate supply. Smaller motors use a brushless exciter instead, like a ship's alternator. |
| Spider | The arms that carry the heavy rim and poles from the shaft. |
| Pedestal bearings | Oil-lubricated sleeve bearings either side, each on its own pedestal. |
At standstill the field sweeps past the rotor's poles far too fast for them to follow, pulling first one way, then the other. A synchronous motor cannot start by itself. So the rotor also carries a cage winding, the damper or amortisseur winding. The motor starts on it as an induction motor, and when it is close to synchronous speed the DC field is switched on and the rotor pulls into step.
The field can only pull the rotor in when the damper bars have brought it close to synchronous speed. The heavier the load, the further behind the field the bars leave it, as with any induction motor. In the lab, start it on full load and it hangs well below speed; lighten the load and it comes close enough to pull in.
When load is added, the rotor does not settle at its new load angle at once. Its inertia carries it past, and it swings back and forth about the new position, slower than the field and then faster. This swinging is hunting. While the rotor moves relative to the field, currents are induced in the damper bars, and their torque opposes the swing until it dies away. In the lab, watch the damper bars glow while the rotor pulls into step, then go dark once it is locked.
Change the DC field current and the motor's power factor changes, without any change of speed. With too little field it is under-excited and draws lagging current like an induction motor; at the right field it runs at unity; with more still it is over-excited and draws leading current, supplying reactive power to the system instead of taking it.
Plot the stator current against the field current at a steady load and the curve has the shape of a V: the V-curve. The bottom of the V is unity power factor, where the current is least. A propulsion motor is run there, so the current, the copper losses and the size of everything that carries it are no larger than the kW demands. A synchronous motor run with no load purely to supply reactive power is a synchronous condenser.
Load the motor more and more and the load angle grows. Past 90° the torque begins to fall instead of rise, the rotor cannot hold the field, and it pulls out of step: the poles slip past the field one after another, the torque swings violently, the current surges, and the motor stalls unless it is tripped. Weakening the field does the same, because a weaker field gives less torque at every angle. In the lab, the protection trips the motor after two seconds of slipping poles.