Temperature sensors

How each type of temperature sensor works, in plain terms: thermocouple, RTD (PT100), thermistor, bimetallic strip, filled-system thermometer and infrared, and where you find each on a ship.

Sensors and instrumentation, page 1 of 64 min readUpdated 4 November 2026All 6 pages

Every temperature sensor does one job. It turns a temperature into something a system can read: a small voltage, a change of resistance, or a movement. Which of the three it uses is what separates the types below. All but the last one touch what they measure; the last one reads the heat it gives off.

An interactive oil bath with three temperature sensors loads here. It needs JavaScript; the sections below explain everything it shows.

Thermocouples

Join two wires of different metals at one end and heat that joint, and a small voltage appears between the two free ends. This is the Seebeck effect. The voltage depends on the difference in temperature between the hot joint and the far ends, so the instrument reading it also has to know the temperature at its own end. The common type K gives about 41 µV for every degree.

A thermocouple needs no power supply and stands very high temperatures, so it is the sensor in the hot places.

On board: the exhaust gas temperature after each cylinder of the main engine and the generators, and at the turbocharger.
Resistance temperature detectors (RTDs)

The resistance of a pure metal rises steadily as it warms. A resistance temperature detector is a fine platinum wire or film; pass a small current through it, measure its resistance, and you have its temperature. The standard one is the PT100: 100 Ω at 0 °C, rising to about 138.5 Ω at 100 °C.

An RTD is accurate and stable across the temperatures machinery runs at, and it is the most common temperature sensor on board.

On board: bearings, lubricating oil, cooling water, and the stator windings of generators and large motors.
Thermistors

A thermistor is a small bead of semiconductor whose resistance changes far more with temperature than a metal's does. Most have a negative coefficient (NTC): their resistance falls as they warm. The positive kind (PTC) works the other way, and some are made to stay low until a set temperature and then rise very sharply.

That sharp rise makes a PTC thermistor a switch rather than a gauge. Buried in a motor's winding and wired to a relay, it trips the motor when the winding itself gets too hot, whatever the cause.

On board: PTC thermistors in the windings of motors, with their relay in the starter, and NTC thermistors in electronics and air conditioning.
Bimetallic elements

Two strips of metals that expand by different amounts are bonded together. When the strip warms, one side grows more than the other and the strip bends. That movement can turn a pointer, or open and close a contact.

On board: dial thermometers on pipework, thermostats, and the thermal overload relay in a motor starter, where the motor's current heats the strip until it bends far enough to trip.
Filled-system thermometers

A bulb filled with liquid or gas sits in the hot medium, joined by a thin capillary tube to a gauge. As the bulb warms, its filling expands and the pressure moves a pointer. The gauge can be a few metres away from the bulb, and nothing electrical is involved. The ordinary glass thermometer works the same way, with the liquid rising up the stem.

On board: local temperature gauges on engines, coolers and tanks, read on rounds.
Infrared thermometers

Everything warm gives off infrared radiation, and the hotter it is the more it gives off. An infrared thermometer or thermal camera measures that radiation, so it reads a temperature from a distance, without touching the surface.

On board: a thermal camera or infrared gun for finding hot connections in switchboards and starters, and hot bearings, while the plant is running.
Comparison
TypeWhat changesTypical place on board
ThermocoupleMakes its own small voltageExhaust gas temperatures
RTD (PT100)Resistance rises steadilyBearings, oil, water, windings
ThermistorResistance changes sharplyMotor winding protection
BimetallicBendsThermostats, overload relays, dial gauges
Filled systemExpands and pushes a pointerLocal gauges
InfraredReads the radiation given offHot spot checks on running plant
From sensor to signal: 4 to 20 mA

A sensor's own output, a few millivolts or a change of a few ohms, is too small and too easily disturbed to send across an engine room. A transmitter beside the sensor turns it into a standard signal, usually a current of 4 to 20 mA: 4 mA at the bottom of the range, 20 mA at the top. A PT100 transmitter ranged 0 to 200 °C sends 12 mA at 100 °C.

A current is used because it is the same all the way round the loop, whatever the length and resistance of the cable. The range starts at 4 mA, not zero, so that a reading of zero can only mean a fault: a broken wire or a dead transmitter. That raised starting point is called a live zero.

Check yourself
1. Which of these sensors makes its own voltage, with no power supply?
The thermocouple, by the Seebeck effect at the joint of its two metals.
2. What is the resistance of a PT100 at 0 °C?
100 Ω, which is where its name comes from.
3. A motor's winding overheats although its current is normal. What stops it?
The PTC thermistor in the winding: its resistance rises sharply at its set temperature and its relay trips the motor. An overload relay would not see it, because it only measures current.

Going for your ETO CoC oral?

The full Temperature sensors notes (T06), the quiz bank and the questions MMD surveyors have actually asked, each with a model answer, are in the Elec-Buddy app.

Start your free trial

Sources

Where the figures on this page come from, by book and printed page or by regulation.

  • IDC Technologies, Practical Instrumentation for Automation and Process Control (2004), chapter 4: thermocouples and the Seebeck emf (section 4.2, p.98), resistance temperature detectors and platinum's coefficient of about 0.00385 Ω/Ω/°C (4.3, p.110), thermistors, NTC and PTC (4.4, p.118), liquid-in-glass, filled and bimetallic thermometers (4.5, p.122), non-contact pyrometers (4.6, p.130).
  • Fernandez, E.A. Marine Electrical Technology: 13.16.5 Thermistor-based Protection (p.547), PTC thermistors in motor windings tripping on the winding's own temperature; the thermal overload relay's bimetallic strip (p.438); resistance and thermistor detectors on generator windings, bearings and cooling (6.10.1, p.194).
  • Elec-Buddy notes: T06 Sensors and Instrumentation (PT100, 100 Ω at 0 °C and 138.5 Ω at 100 °C; type K about 41 µV/°C; cold junction compensation), T12 Cables (infrared hot spot checks).
  • The lab uses the figures on this page: a PT100 at 100 Ω at 0 °C with platinum's coefficient of 0.00385 (IDC 4.3, p.110), a type K thermocouple at about 41 µV per degree, taken as linear, and a PT100 transmitter ranged 0 to 200 °C to 4 to 20 mA. The thermistor, 10 kΩ at 25 °C with a B value of 3950, is an illustrative part. An automated test checks its figures against the page.