Alternating current

The sine wave, frequency and period, rms and peak, phase and phasors, and how a resistor, a coil and a capacitor behave on AC.

Electrical fundamentals, page 4 of 63 min readUpdated 4 November 2026All 6 pages

Almost all the power on a ship is AC. The voltage swings positive and negative many times a second. A generator produces it naturally, and a transformer needs it. This page covers what describes a wave, and how resistors, coils and capacitors behave on it.

An interactive AC generator and load loads here. It needs JavaScript; the sections below explain everything it shows.

The sine wave

A coil turning in a magnetic field gives a voltage that rises, falls, reverses and comes back, smoothly, once every turn. Plotted against time it is a sine wave.

  • Frequency (f): how many complete cycles happen each second, in hertz (Hz). Ships run at 60 Hz or 50 Hz, depending on the ship.
  • Period (T): the time for one cycle. At 60 Hz, T = 1 ÷ 60 ≈ 16.7 ms.
  • Peak: the highest value the voltage reaches in each half cycle.
RMS value

An AC voltage is changing all the time, so which value do we quote? We use the rms value: the steady DC voltage that would heat a resistor by the same amount. Every meter and nameplate on board shows rms. For a sine wave the peak is √2, about 1.414, times the rms.

Vpeak = 1.414 × Vrms
a 440 V supply peaks at about 622 V, and the insulation has to stand the peak
Phase angle

Two waves of the same frequency can be in step, or one can rise a little before the other. The gap between them is the phase angle, measured in degrees of a cycle. A phasor draws each wave as an arrow turning at the supply frequency, so you can see the angle between voltage and current at a glance.

Resistance, inductance and capacitance on AC
PartCurrent against voltageOpposition
ResistorIn phaseResistance R, the same at any frequency
Coil (inductor)Lags by 90°Reactance XL = 2πfL, rising with frequency
CapacitorLeads by 90°Reactance XC = 1 ÷ 2πfC, falling with frequency

A coil fights a change of current, so its current comes a quarter cycle late. A capacitor has to charge before its voltage can rise, so its current comes a quarter cycle early. Most real loads mix resistance with reactance. Their combined opposition is the impedance, Z, also in ohms.

A pure coil or capacitor takes no power on average. For half of each cycle it stores energy, in its magnetic or electric field, and for the other half it hands it back to the supply. It still draws current all the time, and that current heats the cables on its way. A resistor is different: its current is in step with the voltage, so the power v × i is positive at every instant, and on average it is V × I with both in rms.

Z = √(R² + X²)
and Ohm's law still holds for AC: V = I × Z
On board: motors and transformers are coils with resistance, so ship's current mostly lags the voltage. How far it lags is the power factor, which has its own page.
Check yourself
1. A supply is 220 V rms. What is its peak?
1.414 × 220 ≈ 311 V.
2. In a pure coil, does the current lead or lag the voltage?
It lags by 90°.
3. What happens to a coil's reactance if the frequency rises from 50 to 60 Hz?
It rises by the same proportion, 20%, because XL = 2πfL.

Going for your ETO CoC oral?

The full Alternating current notes, the quiz bank and the questions MMD surveyors have actually asked, each with a model answer, are in the Elec-Buddy app.

Start your free trial

Sources

Where the figures on this page come from, by book and printed page or by regulation.

  • Wadhwa, C.L. Basic Electrical Engineering, chapter 1, AC circuits: phase (1.2, p.51), the rms value (1.4, p.54) and form and peak factor (1.4.1 and 1.4.2, p.55 to 56), phasors (1.5, p.56), a resistor, inductor and capacitor across a sinusoidal source (1.6 to 1.6.2, p.57 to 59), series R-L and R-C circuits and impedance (1.6.3 and 1.6.4, p.60 to 61). The average power into a purely inductive circuit works out to zero (1.6.1, p.59).
  • Hall, D.T. Practical Marine Electrical Knowledge, 3rd ed. (2014), p.50: equipment is rated in rms; the peak is 1.414 times larger, so 440 V peaks at about 622 V.
  • The lab runs a 220 V rms supply into a 22 Ω resistor, or a coil or capacitor sized to 22 Ω of reactance at 60 Hz (58.4 mH and 120.6 µF), using only the relations above. An automated test checks its figures against the page.