An interactive battery bank loads here. It needs JavaScript; the sections below explain everything it shows.
A cell has two plates of different materials in an electrolyte. A chemical reaction between them gives a voltage across the plates. Discharging runs the reaction one way and releases energy; charging pushes current back through and reverses it. A battery is cells joined together.
- Cells in series add their voltages.
- Cells or batteries in parallel add their capacity.
- Capacity is measured in ampere-hours (Ah): a 100 Ah battery can supply 10 A for about 10 hours.
Plates of lead and lead dioxide in dilute sulphuric acid, about 2 V a cell, so a 24 V battery has 12 cells. The acid's specific gravity falls as the cell discharges and rises as it charges, so a hydrometer reading shows the state of charge. Sealed, maintenance-free types need no topping up.
Nickel and cadmium plates in an alkaline electrolyte, potassium hydroxide, about 1.2 V a cell, so a 24 V battery has 20 cells. They stand rough treatment and deep discharge well and last a long time. Their electrolyte's specific gravity does not change with charge, so a hydrometer tells you nothing about how charged they are; use the voltage.
On board, batteries are usually kept on float charge: held at a voltage just high enough to keep them full. Charging, especially a full charge, gives off hydrogen, which is explosive mixed with air. That is why battery rooms are ventilated, and why no naked light, spark or smoking is allowed near them.
Newer ships may also carry large lithium-ion battery systems for energy storage or hybrid propulsion. They hold far more energy for their size, and need their own monitoring and fire precautions.